110 Bridging
LLC2 Local Termination
LLC LT Profile
Table
Configuration
These parameters make up the LLC LT Profile Table.
Tx Window Size
Range: 1 to 15
Default: 7
Description: Transmit window size is the maximum number of I frames a
station may transmit without acknowledgment.
Boot Type: Node Boot
LCC LT WAN Data Priority
Range: HIGH, MEDIUM, LOW
Default: HIGH
Description: Specifies the transmission priority of the LLC LT data.
Boot Type: LLC LT WAN Parameters.
Entry Number
Range: 1 to 8
Default: 1
Description: Entry number used to reference this table record.
Boot Type: N/A
LCC Profile Name
Range: 0 to 8 (alphanumeric, space blanks field)
Default: (blank)
Description: Local Term Station Table references this parameter for the T1, T2,
TI, N2, N3, and TW values.
Boot Type: Tables and Node Record.